  dsp series 1 dsp series 7.5w to 100w low profile din rail mount power supplies key market segments & applications building services alarms and security, automation: access and fire safety systems, lighting and environment control systems. ? low profile for building automation ? 5v to 24v outputs ? wide range ac input ? -25c to +71c operation ? convection cooled ? ul1310 class 2 ? class ii double insulation dsp features and benefits features benefits ? low 56mm profile ? fits into wall mounted cabinets ? wide range ac ? global use with no input selector switches ? convection cooled ? no system fan required specifications model dsp10 dsp30 dsp60 dsp100 items ac input voltage range vac 90 - 264vac, class ii double insulated (no ground connection required) input frequency hz 47 - 63hz dc input voltage range vdc 120 - 370vdc inrush current (115 / 230vac) a 15 / 30a 25 / 50a 30 / 60a 30 / 60a power factor meets en61000-3-2, en61000-3-3 output voltage accuracy % 1% of nominal line regulation % 1% load regulation % 1% ripple and noise (20mhz bw) mv 50mv (1) overcurrent protection (typ) - 110 - 160%, fold forward under short circuit (dsp100-24/c2 102-108%) overvoltage protection v 120 - 145% hold up time (115vac input) ms see model selector led indicators - green led = on, red led = dc output low operating temperature - -25 to +71c (derate linearly 2.5%/c from 55 to 71c) temperature coefficient %/c 0.02%/c storage temperature - -25c to +85c operating humidity - 20 - 95% rh (non condensing) cooling - convection withstand voltage - input to output 3kvac for 1 min. isolation resistance >100m at 25c & 70%rh, input to ground 500vdc vibration (operating) iec60068-2-6 (mounting by rail: random wave, 100-500hz, 2g, ea. along x, y, z axes 10min/cycle, 60 min) shock (operating) iec60068-2-27 (half sine wave, 4g, 22ms, 3 axes, 6 faces, 3 times for each face) safety agency approvals - ul1310 class 2 (2) , ul508 listed, ul60950-1, en60950-1, ce immunity - en61000-4-2, -3, -4, -5, -6, -8 & -11 conducted & radiated emi - en55022 class b en55022 class a weight (typ) g 60 200 250 320 size (wxhxd) mm 18 x 91 x 55.6 53 x 91x 55.6 71 x 91 x 55.6 90 x 91 x 56.8 case material - plastic warranty yrs 3 note 1: for dsp100-24/c2 ripple & noise measured with vin 115- 230 vac note 2: excludes models: dsp60-5, DSP60-12, dsp100-12, dsp100-15, dsp100-24
dsp series 2 model selector model voltage voltage current power efficiency holdup time (v) adjust (v) (a) (w) (typ %) 115vac in (ms) dsp10-5 5 none 1.5 7.5 74 10 dsp30-5 5 5 - 5.5 3.0 15.0 74 25 dsp60-5 5 5 - 5.5 7.0 35.0 80 16 dsp10-12 12 none 0.83 10.0 78 10 dsp30-12 12 12 - 14 2.1 25.2 82 25 DSP60-12 12 12 - 14 4.5 54.0 84 16 dsp100-12 12 12 - 14 6.0 72.0 82 16 dsp10-15 15 none 0.67 10.1 78 60 dsp30-15 15 13.5 - 16.5 2.0 30.0 83 25 dsp60-15 15 13.5 - 16.5 4.0 60.0 85 12 dsp100-15 15 13.5 - 16.5 5.0 75.0 85 16 dsp10-24 24 none 0.42 10.1 80 60 dsp30-24 24 24 - 28 1.3 31.2 83 25 dsp60-24 24 24 - 28 2.5 60.0 86 12 dsp100-24/c2 24 20 -24.2 3.8 91.2 89 10 dsp100-24 24 24 - 28 4.2 100.8 85 10 mm [inch] 14.20 9.75 43. 1 91.00 32.10 49.00 55.6 18.00 91.00 1 2 ln 34 outline drawing dsp10 series
dsp series 3 mm [inch] 53.00 91.00 14.20 9.75 43. 1 91.00 32.10 49.00 55.6 1 4 5 6 l n outline drawing dsp30 series mm [inch] 71.00 91.00 14.20 9.75 43.1 91.00 32.10 49.00 55.6 1 4 56 dc lo dc on outline drawing dsp60 series mm [inch] 91.00 32.10 49.00 56.8 14.20 9.7 5 43. 1 91.00 89. 9 1 4 56 outline drawing dsp100 series
dsp series dsp april12 v6 4 local distribution tdk-lambda emea www.emea.tdk-lambda.com tdk-lambda france sas route de grivery zac des delaches cs 41077 91978 courtaboeuf cedex france tel: +33 1 60 12 71 65 fax: +33 1 60 12 71 66 france@fr.tdk-lambda.com www.fr.tdk-lambda.com italy sales office via dei lavoratori 128/130 20092 cinisello balsamo (mi) italy tel: +39 02 61 29 38 63 fax: +39 02 61 29 09 00 info.italia@it.tdk-lambda.com www.it.tdk-lambda.com tdk-lambda germany gmbh karl-bold-strasse 40 77855 achern germany tel: +49 7841 666 0 fax: +49 7841 5000 info.germany@de.tdk-lambda.com www.de.tdk-lambda.com austria sales office aredstrasse 22 2544 leobersdorf austria tel: +43 2256 655 84 fax: +43 2256 645 12 info.germany@de.tdk-lambda.com www.de.tdk-lambda.com tdk-lambda uk ltd. kingsley avenue ilfracombe devon ex34 8es united kingdom tel: +44 (0) 12 71 85 66 66 fax: +44 (0) 12 71 86 48 94 powersolutions@uk.tdk-lambda.com www.uk.tdk-lambda.com tdk-lambda ltd. kibbutz givat hashlosha 48800 israel tel: +9 723 902 4333 fax: +9 723 902 4777 info@tdk-lambda.co.il www.tdk-lambda.co.il russia technical support: st petersburg tel: +7 (812) 6580463 sales: moscow tel: +7 (499) 7557732 info@tdk-lambda.ru www.tdk-lambda.ru distribution: rsg electronic components gmbh sprendlinger landstr. 115 d-63069 offenbach / germany tel. +49.69.984047-0 fax +49.69.984047-77 info@rsg-electronic.de www.rsg-electronic.de ?nderungen vorbehalten / subject to change without notice.


▲Up To Search▲   

 
Price & Availability of DSP60-12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X